Cadd Standards Distribution List

We do anticipate that the CADD Standards for Highway Plans policy (version 2.0) will be periodically updated and/or modified. Initially, only errors will be corrected. Individual preferences and ideas will be considered. Recommendations for changes may be discussed with members of the CADD Standards committee.

An email will go out to communicate CADD Standards updates. Anyone wishing to receive these email updates needs to sign up here:

Type your full email address here. (john.doe@email.com)

Current Software Releases recognized by KYTC CADD Standards:

MicroStation Version 08.05.02.35 Windows x86

Bentley InRoads 2004 Edition V08.05.00.00 Service Pack 4

KYTC CADD Standards Version 2.08.00

    
* Notice this is a self extracting executable
   for use with Bentley MicroStation V8.

New!! Download the Data Set from the MicroStation 2 Class

Inroads Survey Users Please see tech notes listed below

 

Updates and Changes

* InRoads Users: Should use SP4.

What is new/ changed in KYTC STANDARDS!

January 18, 2007

v02.08

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

  • KYTC CADD Standards Policy
    • Updated the CADD Standards Policy to reflect Design Memorandum 18B-05 "Supplemental Electronic Project Files".

July 25, 2006

v02.07

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

  • Seed Files
    • Changed the Working Units Resolution to Survey Foot in the KYTC_2D and KYTC_3D seed files.
  • Cell Libraries
    • Changed EC_NOTES Verbiage changed per Drainage Section.
  • Levels: (dgnlib)
    • Created level R_IN_EWRKC_PR & R_IN_EWRKF_PR.
  • InRoads
    • Changed the Symbology "PR Grade Line" to place the cell Misc. Loc. Point at all vertical points, except Event, High and Low Points.
  • Settings Manager
    • Created components for PR & EX HEC-RAS Sections, as well as Top of Bank and Over bank.
  • Other
    • Changed Version.txt to read 2.07.00

 

March 28, 2006

v02.06.01

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

Seed Files

    • Changed the Global Origin in the 2D and 3D seed files.

March 27, 2006

v02.06

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

Seed Files

    • Changed the Working Units to Survey Feet in the 2D and 3D seed files.

Cell Libraries

    • Changed Sheet cell SPP so that the grids spacing is correct.

 

    • Changed Sheet cell STHA to show Northing/Easting coordinate columns.

Levels: (dgnlib)

    • Created level R_XS_SUBGRADE_PR (Proposed Subgrade).

InRoads

    • Changed the Symbology in the civil_V2.ini file to correctly place the Point Symbology for EX Sewer (Sanitary) on the proper level (R_XS_SAN_ET).

Other

    • Add font 42 to KYTC_Font.rsc. This is to be used for KYTC Standards Drawings only.

 

    • Changed Version.txt to read 2.05.00

* InRoads Users: Should use SP1 until further notice. SP2 and SP3 are not compatible with KYTC Standards and SP4 is under evaluation.

January 20, 2006

v02.05.01

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

  • Seed Files
    • Changed the Global Origin in the 2D and 3D seed files.

January 6, 2006

v02.05

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

  • Cell Libraries
    • Changed vault dimensions of all Manhole Type C in X-Section cells to reflect the standard drawings.
    • In sheet cells SXSP, SXS, SXSPF & SXSF (Cross Section w/o Gridlines, Cross Section w/ Gridlines, First Cross Section w/o Gridlines & First Cross Section w/ Gridlines), moved the scale just to the left of the info box in the lower right hand corner so that it will no longer fall within the cross section offset datum. Also changed Cross Section preferences in civil_V2.ini so that 5, 10, 20, 30 & 40 Scale cross sections using InRoads grid lines will use the sheet cell SXSP.
    • Moved the origin point for "N equals", "Shelby Test" and "SDI Arrow" in the Geotech Cell Library.
    • Changed cell “EC_LEGEND” to read "SILT TRAP TYPE C” instead of Silt Check Type C in the Drainage Cell Library.
    • Eliminated the elevation column from the Right of Way Monument Points cell “NRWMSI” in the Roadway Cell Library.
    • Revised MEDGEKEY1 (Tapers @ Entrances) & MEDGEKEY2 (Tapers for High Speed Roadways) cells and added MEDGEKEY3 (Tapers for Low Speed Roadways) to the Roadway Cell Library.
    • Added a cell for FHWA Signature (SFHWAS) to the Sheet Cell Library.
    • Added cells for PR and EX Control of Access in X-sec (EXSCOA & PXSCOA) to the Roadway Cell Library.
    • Changed EC_NOTES to add more Erosion Control verbiage.
    • Turned on the "Is cell" button for the Default cell. And also dropped the shared cells out of SPL and put the e-sheet name text on level SB_PL_EDATA_PR.
    • Fixed cells EPFOVHD, EXSGLELE, EXSSAN, EXSSS, EXSTELELELOC, EXSUEL, EXSUTC, EXSUTV and EXSWL to better display the SUE Quality Level A survey elevation in cross section.
    • Created a cell (JBXB PLAN) for Junction Boxes with lids and deleted the lid from the Junction Box Plan cell (JBX PLAN) in the Drainage Cell Library.
    • Added a cell for the Law Enforcement Officer Note for Traffic Control Notes (NLEO). Note is found in the Roadway Cell Library.
    • Added cells for 32” and 50” Concrete Median Barrier Walls, both double and single sided (PBW3212, PBW3212H, PBW3214, PBW3214H, PBW329, PBW329H, PBW5012, PBW5012H, PBW5014, PBW5014H).
  • Levels: (dgnlib)
    • Created a filter in the STLevel,dgnlib.
    • Created Top of Slope & Bottom of Slope levels (R_PL_TOS_EX & R_PL_BOS_EX).
    • Created level R_PL_VBFEN_PR (Proposed Visual Barrier Fence).
    • Created levels for Auto TURN simulations, including: Turning Path, Front Tire Tracks, Rear Tire Tracks and Vehicle Body (R_PL_ATPATH_PR, R_PL_ATFTIRE_PR, R_PL_ATRTIRE_PR & R_PL_ATVEH_PR).
    • Created three Drainage Area Levels (R_PL_DA1_PR, R_PL_DA2_PR, & R_PL_DA3_PR) and the respective annotation levels (R_PL_DA1_PT, R_PL_DA2_PT, & R_PL_DA3_PT). Removed the Proposed Watershed Level (R_PL_WTRSHD_PR) and its respective annotation level (R_PL_WTRSHD_PT).
    • Created a level for Edge of Pavement lines in Profile (R_PF_EOP_PR).
    • Created a level for Existing Miscellaneous Recreational Facilities (R_PL_REC_EX).
    • Created levels for Coordinate Grid Tics and Annotation (R_PL_CGT_EX & R_PL_CGT_ET).
  • Settings Manager
    • Created Components in Settings Manager for patterning Asphalt, Gravel and Concrete for Typical Sections.
    • In Settings Manager, edited the “Project Number and Description” text component to be 0.24 instead of 0.5 so that it will be set-off from the county name above it and also to allow more information to be placed in the space provided.
    • Pointed EC- Ditch component back to the appropriate level, R_EC_DITT_PR.
    • Changed Settings Manager component to reflect the correct level for Median Barrier Walls (R_XS_MB_PR).
    • Fixed the broken level link for the Settings Manager component “Project Info Upper Right” in the Layout Sheet group.
    • Created a component for Edge of Pavement Profiles.
    • Created the 30 Scale component (1"=30') in Settings Manager.
  • Other
    • Made the RW Summary macro turn off the display of data fields.
    • Created a new custom pallet named KYTC Standards Checker.
    • Changed RWSum Master.xls area(s) remaining SQ.FT. to use 43560.
    • Changed Version.txt to read 2.05.00
    • In the KYTC Roadway custom pallet, changed the “EX Planimetric” toolbar buttons for barrier walls and retaining walls to reflect the correct levels.
    • Recreated the KYTC Seed.upf file to allow the user to see the file history in MicroStation.
  • InRoads
    • Created codes in the Survey Feature Table: TW for Thalwegs and BF for Bank- Full points. Used EX Flow Line level for Thalwegs and a Misc. InRoads point for the Bank-Full symbology.
    • Set PVRC & PVCC points and text, as well as Sub-Tangent lines, to appropriate symbology.
    • Changed the Symbology in the civil_V2.ini file to correctly place the Proposed Exterior Boundary on the proper level (R_IN_EBNDRY_PR).
    • Created a Feature Style “EX Ground Line”; also set the Symbology for Edge of Pavement to project a profile line with the level attributes of the Proposed Centerline for creating Edge of Pavement Profiles.
    • Corrected the symbology for EX Gate and mapped it to the Feature Code GATE.
    • For each scale in the InRoads Options, the cell scale factor is set to 1. In order to ensure that the user has his/her scales set to the desired default; they will have to set the Preferred Preference on the General tab to the desired scale. Then InRoads will be set to the corresponding scales by default when it is started.
    • Updated the Vertical Design Checks.txt and Horizontal Design Checks.txt to AASHTO 2004.
    • Changed the Edge of Pavement Profile line symbology to display the level R_PF_EOP_PR [Proposed Edge of Pavement Profile Line (Mainline, Approaches, and Ramps)].

May 25, 2005

v02.04

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

  • Cell Libreries
      • Checked the “Is Cell” check box in the KYTC_Sheet cell library for sheet cells SPL and SCOE so that they will be listed in the cell library dialog box.
      • On cell SPL & SPPFL, changed the line weights of the ltems in the legend to correctly reflect the proper weights for each corresponding Roadway level.
      • Added PR ROW and Easement Lines to the EC Legend cell in KYTC_Drainage.cel. Also removed the flat bottom ditch silt check symbol form the legend.
      • Removed EC_SC_STRAW (Straw Bale Silt Check) from KYTC_Drainage.cel as this type of check is no longer used.
      • Changed annotation in KYTC_Roadway cell ESANMH (Existing Sanitary Manhole) from SS to SAN.
      • Created cell NRWMSI2 for ROW Monumentation that does not require State Plane Coordinates.
      • Changed cells ERWPN1 &ERWPN2 to use font 23 and EMINPN1 & EMINPN2 to use font 80.
      • Added data field to SL (Layout Sheet) for Project Description/Project number.
      • Corrected Drainage cell DB01_X (DBI Type 1 in X-Sec) to reflect Standard Drawing. Also corrected cell HDWL_15SF (15” S&F Headwall) to match the Standard Drawing.
      • Changed the cell descriptions of cells MTAO, MTASF, MTAF & MTASO to reflect their use on Maintenance of Traffic Plans. Created the same versions of cells for use on Plan Sheets and Detail Sheets (MDAF, MDAO, MDASF, MDASO, MPAF, MPAO, MPASF, MPASO).
      • Fixed the following Manhole Type C cells in the KYTC Drainage cell library to reflect vault dimensions consistent with the Standard Drawings for circular pipes: (MHC_X30, MHC_X36, MHC_X42, MHC_X48, MHC_X54, MHC_X60, MHC_X66 & MHC_X72).
      • Changed the justification of the data field for Project Description/Project Number on the Layout Sheet cell (SL) so that multi-line text will be forced downward from the current position and not encroach on the text above.
      • On Cross Section Sheet Cells (SXSP & SXSPF), moved the scale data field to position just to the left of the project info block lower right so that it doesn’t fall with the cross section gridlines.
  • Levels: (dgnlib)
      • Changed the level R_DS_ANNO_PR (Proposed Detail Annotation) to R_DS_ANNO_PT to reflect a text/annotation level.
      • Changed the color of Ex Mineral Parcel levels from 128 to 12, including cells EMINPN1 & EMINPN2. Changed the line style of R_PL_ML_EX (Existing mineral Parcel Line) to style 7.
      • Created Levels R_PL_LNO_EX & R_PL_LNO_ET (Existing Line No. and Annotation) as well as R_PL_XSEC_EX (Existing Cross Section).
      • Created levels for PR Silt Basin and Annotation (R_PL_SLTBSN_PR & PT) and PR Detention/Retention Basin and Annotation (R_PL_BASIN_PR & PT).
      • Changed the name of the level for EX Shrub Line from R_PL_SL_PR to R_PL_SL_EX.
      • Created level R_PL_RWCALL_ET (Existing ROW Calls).
      • Created level R_PL_UTOWNRS_ET (Existing Utility Owners).
      • Modified level R_PL_PLL_PR (Proposed Lane Lines) as follows: changed linestyle to 3 and weight to 1.
      • Created level R_PL_CCBAR_EX (Existing Crash Cushions and Other Barriers).
      • Created following levels for the Layout Sheet: R_LS_ROUTE_ET (Existing Route Names and Markers), R_LS_MAP_PR (Proposed Layout Sheet Map) & R_LS_SCALE_PR (Proposed Graphic Scale.
      • Created level R_PL_PLABEL_PT (Proposed Primary Roadway Labeling) for labeling Ramps Route #s, etc.
  • Settings Manager
      • Changed the text size for EX Mineral Parcel Line Annotation to 0.14 and a text spacing of 0.07.
      • Added components for PR Detention/Retention Basin & Annotation, as well as PR Silt Basin & Annotation.
      • Fixed the EX Shrub Line component to place graphics on the appropriate level (R_PL_SL_EX).
      • Changed the text size of all Parcel Owners from 0.18 to 0.14 to match the standards policy.
      • Added component for Project Description/Project Number on Layout Sheet and set text size to 0.3 and font to 92.
      • Corrected MISC Notes in MISC Pipe Sheet Items to place text on correct level (R_PD_MISC_PT).
  • Other

 

  • InRoads
      • Updated the civil_V2.ini file to include Feature Styles that reflect our survey codes, so that survey information from the data collector will map with the correct symbology.
      • Changed the size of Horizontal Stationing Ticks to 0.1 for Majors and 0.08 for Minors. Also set the Level Symbology to the correct level (R_PL_PCLTIC_PR).
      • Changed the bottom margin on the Create Cross Section Spacing tab to better center and align the grids with the vertical datum. This applies to the preferences that place SXS and SXSF sheet cells around the sections.
      • Created a preference for flagging MOT construction item with View Stationing: PR Construct note MOT.
      • Changed the Create Cross Section preference for all scales that use sheet cells without gridlines. Preference will now place sheet cells SXSP and SXSPF around sections instead of that standard plan sheet cell.
  • Appendix

 

Feb. 24, 2005

v02.03

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

 

  • Cell Libraries:

 

  • KYTC_Sheet: SCOE, SGS, SL, SPL, SRWA1, SRWA2

 

  • KYTC_Roadway: NCCS5, NCCS6, NCCS7, NCCS8, NCCS9, NNHS1, NNHS2, ESSMH, EDBI, ECBI. Parcel Owner cells were renamed to ERWPN1, ERWPN2, EMINPN1 and EMINPN2 and moved to the correct levels.

 

  • KYTC_Drainage: EC_ST_CBI_FULL, EC_ST_CBI_HALF, EC_ST_C_DBI, EC_LEGEND, EC_NOTES, EC_DDA_CHART, EC_TRAP_INFO and EC_ST_C_HDWL
  • KYTC_Geotech: Hole C, Hole D and Talus also changed the level these cell were on: 7575, 150150, 300300, 600600, ARS, BLOG, CORE, DATA, DISCL, ELEV, IS, IS2, MAPDATA, NOSTAB, PREN, RDZ, RQDREC, SAND, SC, SHALE1, SHALE2, SINK, STDATA

 

  • KYTC_Traffic: Sig_head270, Sig_head90, Sig_head NA, Sig_head 180, SigHead 0, Pedhed_na , pedhed 270, pedhed 180, pedhed 90, pedhed, Loop_5cut 270, Loop_5cut 189, Loop_5cut 90, Loop_5_cut

 

 

Levels: (dgnlib)

 

STLevel.dgnlib has been updated to have the proper line style for levels S_PL_Rebars_PR and S_PL_CntrLn_PR.

 

Level filters recreated in RWLevel.dgnlib file.

 

 

RWLevel.dgnlib has been updated to remove level 203 (R_PL_DITT_PR) Proposed Ditches (Temporary) and add level 2610

(R_EC_DITT_PR) Proposed Erosion Control (Temp. Silt Ditch)

 

 

 

  • Setting Manger:

 

  • Working Units were taken out because they are no longer need.

 

  • Updated the PR Const. Items (Plan), Storm Sewer component.

 

  • Updated the PR Const. Items (Plan), various Erosion Control components.

 

  • Updated the EX Planimetric (Plan) to include Existing Landscaping (Excludes Vegetation and Trees) Existing Rip Rap, Existing Centerline, and Existing Centerline Annotation.

 

  • Other:

 

  • Changed KYTC_Line.rsc file so that text will orient itself properly regardless of how it was drawn.

 

  • Updated the Traffic custom pallet.

 

 

Inroads:

 

  • Created symbology for Sub-Tangent lines in Profile and turned on the sub-tangent line in View Vertical Alignment.

 

  • Created a Feature Style for Random/Mass points and linked it with the symbology for MISC InRoads points.

 

 

Appendix

 

  • Revised the CADD Standards Policy Documentation to include “MP” as a Roadway Sheet Code for Mitigation Plans.

 

 

 

  • Revised the CADD Standards Policy Documentation to include Level R_PL_RWPOPN_ET (828 - Existing R/W Property Owners & Parcel Numbers) Color = 7, Style =0, Weight = 1, Font = 23, Text Size =0.18 as well as changed level R_PL_MP_ET (832 - Existing Mineral Parcel Owners & Parcel Numbers) font to 80.

 

  • Revised the CADD Standards Policy Documentation to include levels for MISC Graphics and MISC Notes in PL, PF, PD & XS, various Erosion Control components in the PR Const. Items (Plan) and revised the line style component for the Storm Sewer in PR Const. Items (Plan).

 

Dec. 08, 2004

 

The changes that have been made to the KYTC Standards Version 2.01 CADD Standards

 

  • Updated Cell Libraries:

 

  • KYTC_Sheet.cel: SGEO,SL and SIGNSUM3

 

  • KYTC_Roadway: NNHS1, NNHS2, and Changed all text of size 0.175 to 0.18 for rounding purposes in InRoads.

 

  • KYTC_Drainage: DB11_X, FLUME_TY1, FLUME_TY2_AH, FLUME_TY2_BK, MHA, MHB created 9 cells for Concrete Median Barrier Box Inlets, changed all Curb Box Inlet cells in X-Sec so that the aprons match a 2% gutter cross slope and renamed DBITY11 to DB11_PR

 

  • KYTC_Geotech: N equals and Shelby Test

 

Levels:

 

Created R_MS_NHS_PT in the RWLevel.dgnlib file

 

  • Other:

 

  • Changed KYTC_Line.rsc file so that text will orient itself properly regardless of how it was drawn.

 

  • Fixed E-Sheet Macro save views

 

  • Fixed the error message within the executable

 

Inroads:

 

  • Updated the Civil_V2.ini file to include some Storm and Sanitary

 

 

 

 

Nov. 18, 2004

 

The changes that have been made to the KYTC Standards Version 2.0 CADD Standards

 

  • Updated Cell Libraries:

 

  • KYTC_Sheet.cel: SGSPDPA, SIGNSUM3, SL, SPF, SPL, SPP, SPPF, SPPFL, SPS, SPSPA, SQUAN, SRWA1, SRWA2, SRWSM, SSP, SSPG, SSPF, SSPFGR, SXPD. Fixed the data fields for the Auto Fill In.

 

  • KYTC_Roadway.cel: EINR_PNT, PINR_PNT, PRWPN1, PRWPN2, NCCS3, NCCS4, NCCS5, NRWMS1.
  • KYTC_Traffic.cel: leg_sig_all, leg_sig_3, leg_loop_sch

 

Levels:

 

Created levels for MISC. Graphics & MISC. Notes in PL, PF, PD & XS

 

  • Removed the two levels from EX Utilities and put them in EX Survey.

 

  • Move the Property Owner levels to EX R/W grouping. And also changed the Mineral Owners and Parcel Numbers level to color 7.

 

  • Changed the text size for P_PF_DATUM_PT from 0.18 to 0.14 to accommodate four digit elevations on the girded profile sheet cells.

 

Inroads:

 

  • Updated the Civil_V2.ini file to include Profile Preferences for 10, 20, 30, 40, 50 & 100 Scale plans.

 

  • Updated Preferences for X-Sec to include 30 & 40 Scale sheets.

 

  • Created preferences for Plan & Profile Generator.

 

 

  • Also set the origin of a custom cross section to a point where a regular plan sheet cell (SP) can be used for a sheet border.

 

  • Added Feature Styles for Storm & Sanitary.

 

  • Created Preferences for Storm & Sanitary.

 

  • The Storm & Sanitary structures file is now included in the executable file, kytc_i_structures.dat.

 

  • Created a .dft file for use with InRoads Drafting Tools for placing Profile and X-Sec notes with proper ByLevel symbology.

 

  • Updated the kytc_V2.fwf file (Feature Codes) to properly display on the screen before written to graphics.

 

  • Updated Template libraries.

 

 

Appendix

 

  • Revised Data Fields Portion of the CADD Standards V2.0 Policy Appendix to state that the Data Field view does not have to be on in order to use Data Fields and referred users to MicroStation Help for more information concerning Data Fields.

 

  • Added both levels to the Appendix Excel file.

 

Other

 

  • Changed the Override Custom Line Styles Scale Factor to 50

 

  • Add a KYTC Version button. It is located in the Menu Bar.

 

  • In Setting Manger Disturbed Limits component moved into PR Construction (Plan)

 

  • Set "units.def" file to us U.S. Survey Feet. Then put it in the data folder as well as adding the configuration variable MS_CUSTONUNITDEF to all of the *.pcf

 

  • Updated PDF’s for cell libraries: KYTC_Sheet, KYTC_Roadway, KYTC_Traffic

 

  • Updated the Roadway custom pallet.

 

 

May 25, 2005

v02.04

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

 

  • Cell Libreries
      • Checked the “Is Cell” check box in the KYTC_Sheet cell library for sheet cells SPL and SCOE so that they will be listed in the cell library dialog box.

 

      • On cell SPL & SPPFL, changed the line weights of the ltems in the legend to correctly reflect the proper weights for each corresponding Roadway level.

 

      • Added PR ROW and Easement Lines to the EC Legend cell in KYTC_Drainage.cel. Also removed the flat bottom ditch silt check symbol form the legend.

 

      • Removed EC_SC_STRAW (Straw Bale Silt Check) from KYTC_Drainage.cel as this type of check is no longer used.

 

      • Changed annotation in KYTC_Roadway cell ESANMH (Existing Sanitary Manhole) from SS to SAN.

 

      • Created cell NRWMSI2 for ROW Monumentation that does not require State Plane Coordinates.

 

      • Changed cells ERWPN1 &ERWPN2 to use font 23 and EMINPN1 & EMINPN2 to use font 80.

 

      • Added data field to SL (Layout Sheet) for Project Description/Project number.

 

      • Corrected Drainage cell DB01_X (DBI Type 1 in X-Sec) to reflect Standard Drawing. Also corrected cell HDWL_15SF (15” S&F Headwall) to match the Standard Drawing.

 

      • Changed the cell descriptions of cells MTAO, MTASF, MTAF & MTASO to reflect their use on Maintenance of Traffic Plans. Created the same versions of cells for use on Plan Sheets and Detail Sheets (MDAF, MDAO, MDASF, MDASO, MPAF, MPAO, MPASF, MPASO).

 

      • Fixed the following Manhole Type C cells in the KYTC Drainage cell library to reflect vault dimensions consistent with the Standard Drawings for circular pipes: (MHC_X30, MHC_X36, MHC_X42, MHC_X48, MHC_X54, MHC_X60, MHC_X66 & MHC_X72).

 

      • Changed the justification of the data field for Project Description/Project Number on the Layout Sheet cell (SL) so that multi-line text will be forced downward from the current position and not encroach on the text above.

 

      • On Cross Section Sheet Cells (SXSP & SXSPF), moved the scale data field to position just to the left of the project info block lower right so that it doesn’t fall with the cross section gridlines.

 

 

  • Levels: (dgnlib)
      • Changed the level R_DS_ANNO_PR (Proposed Detail Annotation) to R_DS_ANNO_PT to reflect a text/annotation level.

 

      • Changed the color of Ex Mineral Parcel levels from 128 to 12, including cells EMINPN1 & EMINPN2. Changed the line style of R_PL_ML_EX (Existing mineral Parcel Line) to style 7.

 

 

      • Created Levels R_PL_LNO_EX & R_PL_LNO_ET (Existing Line No. and Annotation) as well as R_PL_XSEC_EX (Existing Cross Section).

 

      • Created levels for PR Silt Basin and Annotation (R_PL_SLTBSN_PR & PT) and PR Detention/Retention Basin and Annotation (R_PL_BASIN_PR & PT).

 

 

      • Changed the name of the level for EX Shrub Line from R_PL_SL_PR to R_PL_SL_EX.

 

      • Created level R_PL_RWCALL_ET (Existing ROW Calls).

 

      • Created level R_PL_UTOWNRS_ET (Existing Utility Owners).

 

      • Modified level R_PL_PLL_PR (Proposed Lane Lines) as follows: changed linestyle to 3 and weight to 1.

 

      • Created level R_PL_CCBAR_EX (Existing Crash Cushions and Other Barriers).

 

      • Created following levels for the Layout Sheet: R_LS_ROUTE_ET (Existing Route Names and Markers), R_LS_MAP_PR (Proposed Layout Sheet Map) & R_LS_SCALE_PR (Proposed Graphic Scale.

 

      • Created level R_PL_PLABEL_PT (Proposed Primary Roadway Labeling) for labeling Ramps Route #s, etc.

 

 

  • Settings Manager
      • Changed the text size for EX Mineral Parcel Line Annotation to 0.14 and a text spacing of 0.07.

 

      • Added components for PR Detention/Retention Basin & Annotation, as well as PR Silt Basin & Annotation.

 

      • Fixed the EX Shrub Line component to place graphics on the appropriate level (R_PL_SL_EX).

 

      • Changed the text size of all Parcel Owners from 0.18 to 0.14 to match the standards policy.

 

      • Added component for Project Description/Project Number on Layout Sheet and set text size to 0.3 and font to 92.

 

      • Corrected MISC Notes in MISC Pipe Sheet Items to place text on correct level (R_PD_MISC_PT).

 

 

  • Other

 

 

 

  • InRoads
      • Updated the civil_V2.ini file to include Feature Styles that reflect our survey codes, so that survey information from the data collector will map with the correct symbology.

 

      • Changed the size of Horizontal Stationing Ticks to 0.1 for Majors and 0.08 for Minors. Also set the Level Symbology to the correct level (R_PL_PCLTIC_PR).

 

      • Changed the bottom margin on the Create Cross Section Spacing tab to better center and align the grids with the vertical datum. This applies to the preferences that place SXS and SXSF sheet cells around the sections.

 

      • Created a preference for flagging MOT construction item with View Stationing: PR Construct note MOT.

 

      • Changed the Create Cross Section preference for all scales that use sheet cells without gridlines. Preference will now place sheet cells SXSP and SXSPF around sections instead of that standard plan sheet cell.

 

  • Appendix

 

 

Feb. 24, 2005

v02.03

New & Changed

The following outline identifies new features and enhancements in this release of KYTC Standards.

 

  • Cell Libraries:

 

  • KYTC_Sheet: SCOE, SGS, SL, SPL, SRWA1, SRWA2

 

  • KYTC_Roadway: NCCS5, NCCS6, NCCS7, NCCS8, NCCS9, NNHS1, NNHS2, ESSMH, EDBI, ECBI. Parcel Owner cells were renamed to ERWPN1, ERWPN2, EMINPN1 and EMINPN2 and moved to the correct levels.

 

  • KYTC_Drainage: EC_ST_CBI_FULL, EC_ST_CBI_HALF, EC_ST_C_DBI, EC_LEGEND, EC_NOTES, EC_DDA_CHART, EC_TRAP_INFO and EC_ST_C_HDWL

 

  • KYTC_Geotech: Hole C, Hole D and Talus also changed the level these cell were on: 7575, 150150, 300300, 600600, ARS, BLOG, CORE, DATA, DISCL, ELEV, IS, IS2, MAPDATA, NOSTAB, PREN, RDZ, RQDREC, SAND, SC, SHALE1, SHALE2, SINK, STDATA

 

  • KYTC_Traffic: Sig_head270, Sig_head90, Sig_head NA, Sig_head 180, SigHead 0, Pedhed_na , pedhed 270, pedhed 180, pedhed 90, pedhed, Loop_5cut 270, Loop_5cut 189, Loop_5cut 90, Loop_5_cut

 

Levels: (dgnlib)

STLevel.dgnlib has been updated to have the proper line style for levels S_PL_Rebars_PR and S_PL_CntrLn_PR.

Level filters recreated in RWLevel.dgnlib file.

RWLevel.dgnlib has been updated to remove level 203 (R_PL_DITT_PR) Proposed Ditches (Temporary) and add level 2610

(R_EC_DITT_PR) Proposed Erosion Control (Temp. Silt Ditch)

 

  • Setting Manger:

 

  • Working Units were taken out because they are no longer need.

 

  • Updated the PR Const. Items (Plan), Storm Sewer component.

 

  • Updated the PR Const. Items (Plan), various Erosion Control components.

 

  • Updated the EX Planimetric (Plan) to include Existing Landscaping (Excludes Vegetation and Trees) Existing Rip Rap, Existing Centerline, and Existing Centerline Annotation.

 

  • Other:

 

  • Changed KYTC_Line.rsc file so that text will orient itself properly regardless of how it was drawn.

 

  • Updated the Traffic custom pallet.

Inroads:

 

  • Created symbology for Sub-Tangent lines in Profile and turned on the sub-tangent line in View Vertical Alignment.

 

  • Created a Feature Style for Random/Mass points and linked it with the symbology for MISC InRoads points.

 

Appendix

 

  • Revised the CADD Standards Policy Documentation to include “MP” as a Roadway Sheet Code for Mitigation Plans.

 

 

 

  • Revised the CADD Standards Policy Documentation to include Level R_PL_RWPOPN_ET (828 - Existing R/W Property Owners & Parcel Numbers) Color = 7, Style =0, Weight = 1, Font = 23, Text Size =0.18 as well as changed level R_PL_MP_ET (832 - Existing Mineral Parcel Owners & Parcel Numbers) font to 80.

 

  • Revised the CADD Standards Policy Documentation to include levels for MISC Graphics and MISC Notes in PL, PF, PD & XS, various Erosion Control components in the PR Const. Items (Plan) and revised the line style component for the Storm Sewer in PR Const. Items (Plan).

Dec. 08, 2004

The changes that have been made to the KYTC Standards Version 2.01 CADD Standards

  • Updated Cell Libraries:
  • KYTC_Sheet.cel: SGEO,SL and SIGNSUM3
  • KYTC_Roadway: NNHS1, NNHS2, and Changed all text of size 0.175 to 0.18 for rounding purposes in InRoads.
  • KYTC_Drainage: DB11_X, FLUME_TY1, FLUME_TY2_AH, FLUME_TY2_BK, MHA, MHB created 9 cells for Concrete Median Barrier Box Inlets, changed all Curb Box Inlet cells in X-Sec so that the aprons match a 2% gutter cross slope and renamed DBITY11 to DB11_PR
  • KYTC_Geotech: N equals and Shelby Test

Levels:

Created R_MS_NHS_PT in the RWLevel.dgnlib file

 

  • Other:
  • Changed KYTC_Line.rsc file so that text will orient itself properly regardless of how it was drawn.
  • Fixed E-Sheet Macro save views
  • Fixed the error message within the executable

Inroads:

  • Updated the Civil_V2.ini file to include some Storm and Sanitary

Changes made as of 11.18.04

  • Updated Cell Libraries:
  • KYTC_Sheet.cel: SGSPDPA, SIGNSUM3, SL, SPF, SPL, SPP, SPPF, SPPFL, SPS, SPSPA, SQUAN, SRWA1, SRWA2, SRWSM, SSP, SSPG, SSPF, SSPFGR, SXPD. Fixed the data fields for the Auto Fill In.
  • KYTC_Roadway.cel: EINR_PNT, PINR_PNT, PRWPN1, PRWPN2, NCCS3, NCCS4, NCCS5, NRWMS1.
  • KYTC_Traffic.cel: leg_sig_all, leg_sig_3, leg_loop_sch

Levels:

Created levels for MISC. Graphics & MISC. Notes in PL, PF, PD & XS

  • Removed the two levels from EX Utilities and put them in EX Survey.
  • Move the Property Owner levels to EX R/W grouping. And also changed the Mineral Owners and Parcel Numbers level to color 7.
  • Changed the text size for P_PF_DATUM_PT from 0.18 to 0.14 to accommodate four digit elevations on the gridded profile sheet cells.

Inroads:

  • Updated the Civil_V2.ini file to include Profile Preferences for 10, 20, 30, 40, 50 & 100 Scale plans.
  • Updated Preferences for X-Sec to include 30 & 40 Scale sheets.
  • Created preferences for Plan & Profile Generator.
  • Also set the origin of a custom cross section to a point where a regular plan sheet cell (SP) can be used for a sheet border.
  • Added Feature Styles for Storm & Sanitary.
  • Created Preferences for Storm & Sanitary.
  • The Storm & Sanitary structures file is now included in the executable file, kytc_i_structures.dat.
  • Created a .dft file for use with InRoads Drafting Tools for placing Profile and X-Sec notes with proper ByLevel symbology.
  • Updated the kytc_V2.fwf file (Feature Codes) to properly display on the screen before written to graphics.
  • Updated Template libraries.

Appendix

  • Revised Data Fields Portion of the CADD Standards V2.0 Policy Appendix to state that the Data Field view does not have to be on in order to use Data Fields and referred users to MicroStation Help for more information concerning Data Fields.
  • Added both levels to the Appendix Excel file.

Other

  • Changed the Override Custom Line Styles Scale Factor to 50
  • Add a KYTC Version button. It is located in the Menu Bar.
  • In Setting Manger Disturbed Limits component moved into PR Construction (Plan)
  • Set "units.def" file to us US Survey Feet. Then put it in the data folder as well as adding the configuration variable MS_CUSTONUNITDEF to all of the *.pcf
  • Updated PDF’s for cell libraries: KYTC_Sheet, KYTC_Roadway, KYTC_Traffic
  • Updated the Roadway custom pallet
Documentation *Word Format Level Presentation *Excel Format  
The KYTC CADD Standards Policy Download Environmental Download    
Set Up Directions Download Geotech Download    
Electronic Files Checklist Download Roadway Download    
Tech Notes PDF format Sheet Download    
Tech Notes for InRoads PDF format Structures Download    
    Traffic Download    
           
 
** Notice if you need Version 1 of the CADD Standards please go here.
 

If you have any questions or comments about the KYTC CADD Standards email them HERE.